Community Profile

photo

Venkatesh Yadav


USA/India

Attivo dal 2014

Followers: 0   Following: 0

Statistiche

All
  • First Answer
  • Personal Best Downloads Level 4
  • First Review
  • 5-Star Galaxy Level 5
  • First Submission
  • Thankful Level 1

Visualizza badge

Feeds

Visto da

Inviato


Real time Dispatch and Frequency control by WGRs for variable load and wind speed conditions
Real time dispatch and frequency control by WGRs for variable load and wind speed conditions

oltre 8 anni fa | 8 download |

Inviato


Reactive power control for a small wind farm connected to infinite grid
Reactive power control for a small wind farm connected to infinite grid

oltre 8 anni fa | 20 download |

Inviato


Automatic Generation Control by Wind generation resource co-ordinated with synchronous generator
Automatic Generation Control by Wind generation resource co-ordinated with synchronous generator

oltre 8 anni fa | 5 download |

Inviato


AC Microgrid Performance when the main grid is faulted
AC Microgrid Performance when the main grid is faulted

oltre 8 anni fa | 19 download |

Inviato


DC Microgrid performance when the main grid is faulted
DC Microgrid performance when the main grid is faulted

oltre 8 anni fa | 15 download |

Inviato


Automatic Generation Control by Conventional Synchronous Generators
Secondary frequency response or automatic generation control by synchronous generators is explained

oltre 8 anni fa | 9 download |

Domanda


I need a distribution STATCOM with user defined MVAR. How to create it? I know the matlab/simulink has +/- 3 MVAR Statcom model
I need a distribution STATCOM with user defined MVAR. How to create it? I know the matlab/simulink has +/- 3 MVAR Statcom model....

oltre 8 anni fa | 0 risposte | 0

0

risposte

Inviato


Frequency response of grid when suddenly a generator is tripped
Frequency response of grid when suddenly a wind generator trips at t=30 seconds

oltre 8 anni fa | 3 download |

Inviato


Rotor Speed Control- Deloading Control for Frequency Regulation by wind turbines
DFIG operates on a non-optimal power curve @ speed=10 m/s to provide spinning reserves

oltre 8 anni fa | 5 download |

Inviato


Pitch Angle Control for Frequency Regulation
Reserves are created through pitch angle control (Deloading Control) for frequency regulation

oltre 8 anni fa | 5 download |

Inviato


Emulated Inertia Response by Wind Generation Resources - Exact Representation
This file provides the accurate representation of over & under-production phase of Inertial response

oltre 8 anni fa | 7 download |

Inviato


Three Phase Rectifier and Buck Power Conversion System
One folder contains Rectifier and other folder contains buck

quasi 9 anni fa | 3 download |

Inviato


Active and reactive power regulation in a grid integrated with wind power plant
Active and reactive power regulation in a grid integrated with wind power plant

circa 9 anni fa | 16 download |

Inviato


Inertial Response from Wind Turbines
DFIG based Wind turbines providing frequency regulation after a power imbalance

circa 9 anni fa | 6 download |

Inviato


EEG Data Plotting - Power Spectrum, Spectrogram, Frequency spectrum of alpha, beta, delta and theta
An electroencephalogram (EEG) detect electrical activity in brain using electrode attached to scalp.

circa 9 anni fa | 10 download |

Inviato


Buck converter with ESR & ESL and basic converter design without compensation
Buck converter with ESR & ESL and basic converter design without compensation

circa 9 anni fa | 2 download |

Inviato


Frequency response of grid when there is sudden increase in load
Grid consists of conventional power plants and wind power plant

circa 9 anni fa | 2 download |

Inviato


Measure electrical frequency of DFIG (discrete)
Measuring electrical frequency of DFIG (detailed model)

circa 9 anni fa | 6 download |

Inviato


Example of Space vector pulse width modulation
Example of Space vector pulse width modulation

oltre 9 anni fa | 5 download |

Domanda


Could you please provide the phasor model of Wind Farm - Synchronous Generator & Full Converter (Type IV)
Detailed discrete model can be obtained using this command : power_wind_type_4_det Is there any equivalent phasor model for t...

oltre 9 anni fa | 2 risposte | 0

2

risposte

Inviato


Decentralized Combined Heat Power Plant
Model of DCHP for isolated power system. Read the reference [2] for more details

circa 10 anni fa | 16 download |