Domanda


Differences Between Unlimited Nonlinear Iterations and Limiting to 100 Nonlinear Iterations in the Simscape Local Solver
Hi, We are testing the example model: openExample("simscape/MechanicalSystemWithTranslationalFrictionExample") with the Local...

13 giorni fa | 1 risposta | 0

1

risposta

Domanda


Understanding the Mathematical Behavior of the Global and Local Solvers
Hello, We are currently configuring both the global solver and the local solver in our model, but we are struggling to obtain t...

13 giorni fa | 0 risposte | 0

0

risposte

Domanda


Difference between Consistency Tolerance (R2021a) and Tolerance Factor / Absolute Tolerance / Relative Tolerance (R2025b)
Hello, I am migrating a model from MATLAB/Simulink R2021a to R2025b and I noticed that the local solver settings have changed. ...

13 giorni fa | 1 risposta | 0

1

risposta

Domanda


Question about simscape.getLocalSolverFixedCostInfo returning MaxIterations = -1
Hi, I modified the local solver settings in the NonlinearElectromechanicalCircuitWithPartitioningSolver example to intentionall...

13 giorni fa | 1 risposta | 0

1

risposta

Domanda


How can I intentionally trigger a convergence error in a Simulink model?
I have a Simulink model and I am trying to intentionally reproduce a solver convergence error for testing purposes. However, the...

28 giorni fa | 1 risposta | 0

1

risposta

Domanda


How to configure the Simscape Local Solver to guarantee 1 ms real-time execution in a Co-Simulation FMU?
Hello everyone, I am working with a Simulink + Simscape Electrical model that needs to run in real time with a fixed-step size ...

circa un mese fa | 1 risposta | 0

1

risposta

Domanda


Issue with UITable Style Updates After TreeSelectionChanged Event in App Designer
Hi everyone, I’m developing a graphical interface in MATLAB App Designer that includes a UITree and two UITables within the sam...

4 mesi fa | 1 risposta | 0

1

risposta

Domanda


I have a subsystem in Simulink with LConn and RConn blocks, some from Simulink Electrical and others from Simscape. How can I retrieve their type info from MATLAB?
I have a subsystem in Simulink with several LConn and RConn blocks. Some of them are from Simulink Electrical, and others are fr...

oltre un anno fa | 2 risposte | 0