Domanda
Is the bidirectional DC DC converter incapable of boost operation from ports <1+ & 1-> to ports <2+ and 2->?
I am using bidirectional DC DC converter (the prebuilt block) to maintain the output side DC link voltage at a value given by re...
4 mesi fa | 1 risposta | 0
1
rispostaHow to use a real current source?
Hello @Fernando Belda I'm sure you must have solved the problem by now, but just answering for anyone else who comes across thi...
9 mesi fa | 0
Domanda
Why does DQ Current control of 3 phase inverter work with Simscape SPS components but not with Simscape Electrical components?
Hi Community, I am building a current controller for a three phase inverter in the dq frame. I have two models. Both are attach...
9 mesi fa | 1 risposta | 0
1
rispostaHow do I multiplex 3 phase power system signals onto a single signal or generate a varying frequency voltage source
Hello Ciaran, If you connected the three phase signals after the VI measurement block to a three phase RLC load in Simulink, I ...
9 mesi fa | 0
Why is there a huge drop in the values of active and reactive power when the voltage of three phase voltage source is changed?
For Q1) I have figured out that a low value of parameter "Short-circuit power" was causing the issue. I was directly specifying...
9 mesi fa | 0
| accettato
Domanda
Why do I see different measured values for frequency of the same three phase electrical signal while using different PLL & PMU block types?
Hi Community, I have modelled a grid using a programmable three phase AC voltage source and there are three loads attached to i...
9 mesi fa | 1 risposta | 0
1
rispostaDomanda
Why is there a huge drop in the values of active and reactive power when the voltage of three phase voltage source is changed?
Hi Community, I have modelled a grid using a programmable three phase voltage source and there are three loads attached to it. ...
9 mesi fa | 2 risposte | 0
2
risposteDomanda
Why do I see huge voltage spikes at the output of a 3 phase MMC (Modular multi-level converter) in Simscape, when the number of submodules >1, but not with 1 submodule?
Dear Community, I have a three phase bi-directional power converter modelled by the Simscape block Modular Multilevel Converter...
10 mesi fa | 1 risposta | 0