How to use rate limiter with square signal and variable step size?
Hi John, The problem you have is all about sample times, and sample times propagation. In your first example, there is probab...
How to use rate limiter with square signal and variable step size?
Hi John, The problem you have is all about sample times, and sample times propagation. In your first example, there is probab...
quasi 10 anni fa | 0
| accettato
Risposto
How can I define boundary conditions using lsqnonlin solver?
First I'd suggest you to create an m-file to evaluate your error vector. % Example for that function: function Error = Cos...
How can I define boundary conditions using lsqnonlin solver?
First I'd suggest you to create an m-file to evaluate your error vector. % Example for that function: function Error = Cos...
quasi 10 anni fa | 0
| accettato
Risposto
How to read a signal with discontinuities from workspace in simulink?
Normally the problems I've encountered with that error were indeed caused by an Inf or NaN being sent to the integrator. Check...
How to read a signal with discontinuities from workspace in simulink?
Normally the problems I've encountered with that error were indeed caused by an Inf or NaN being sent to the integrator. Check...