Risposto
How to control the speed of the synchronus motor in simscape?
In the attached image there is no control, it is open loop. For learning more about speed control of synchronous machines check ...

10 mesi fa | 0

Risposto
Variable Speed Driver for Induction Motors - Constant V/Hz Control
Simscape Electrical provides a block implementing Scalar Control: https://www.mathworks.com/help/sps/ref/inductionmachinescalar...

10 mesi fa | 0

Risposto
How to implement a V/Hz control transfer function in Simulink?
Simscape Electrical provides a block implementing Scalar Control: https://www.mathworks.com/help/sps/ref/inductionmachinescalar...

10 mesi fa | 0

Risposto
Making a 3 phase semi-controlled converter using Simscape Electrical
In Simscape Electrical it is possible to use the Conveter (Three-Phase) block and set the 'Switching device' parameter to GTO or...

10 mesi fa | 0

Risposto
is it possible to build a controllable load ?
In Simscape Electrical it is possible to use a dynamic load (single-phase or threee-phase). https://www.mathworks.com/help/sps...

10 mesi fa | 0

Risposto
Where can we get description about HVDC control blocks?
If these blocks are part of a MathWorks product (e.g., Simscape Electrical) then you can click on help in the block mask to open...

10 mesi fa | 0

Risposto
Having trouble charging battery using controlled voltage source
I would use a Controlled Current Source instead to charge the battery. See this simple Simscape Electrical example showing how t...

10 mesi fa | 0

Risposto
Converting a sinusoidal signal into a trapezoidal one?
A saturation block can be used to saturate to sine wave so the output will look like a trapezoidal signal. Let’s say we have a s...

10 mesi fa | 1

| accettato

Risposto
DC-DC Buck-Boost Converter Closed Loop PWM control
The proportional control employed is not working properly. The controller is very basic, multiplying the error with a constant b...

10 mesi fa | 0

Risposto
Undefined function 'cos' for input arguments of type 'char'.
inputdlg returns a cell array of character vectors containing one input per edit field, starting from the top of the dialog box....

10 mesi fa | 0

| accettato

Risposto
Why does SIMSCAPE have different values for the speed and the revolutions in the output, although they have to be the same? Is it maybe due to false parameters of the PI-regulator?
There are two issues with this model: i) instead of using electrical angle in the dq-abc block is using the mechanical angle, an...

10 mesi fa | 0

Risposto
Dynamically simulate PMSM motor
The best starting point for understanding how the FEM-Parametrized PMSM block can be configured is the documentation page: http...

10 mesi fa | 1

Risposto
Why PMSM model spins with SVPWM block?
In Simscape Electrical (or other Simulink toolboxes), the models for Permanent Magnet Synchronous Motors (PMSMs) can indeed star...

10 mesi fa | 0

Risposto
How can I use the Battery Equivalent Circuit module and output its SOC?
It is possible to use a Probe block to output internal variables such as state of charge from the Battery Equivalent Circuit blo...

10 mesi fa | 0

| accettato

Risposto
How to measure the frequency of a 3 phase generator in simscape electrical
You can use a Sinusoidal Measurement (PLL, Three-Phase) block in Simscape Electrical. The Sinusoidal Measurement (PLL, Three-Pha...

10 mesi fa | 1

| accettato

Risposto
Switching and Conduction losses of MOSFET
lossesTable = ee_getPowerLossSummary(node) calculates dissipated power losses and switching losses for semiconductor blocks in a...

11 mesi fa | 0

| accettato

Risposto
how should I model the grid for the electrical supply for my Electrolyzer?(simscape)
Probably the best place to start is this example in Simscape Electrical: https://www.mathworks.com/help/sps/ug/green-hydrogen-m...

11 mesi fa | 0

Risposto
Battery Short Circuit Current
That is the short circuit current. As there is no short circuit until 30s the current remains to 0 (Switch is open from 0 to 30s...

11 mesi fa | 1

Risposto
how to make flux based model + inverter
This system can be modeled in Simscape Electrical with existing blocks (PMSM or FEM-Parameterized PMSM and Converter (Three-Phas...

12 mesi fa | 0

Risposto
i need a model of synchronous machines with dampers windinf
Simscape Electrical offers synchronous machine models with both damper windings and without. For synchronous machines with damp...

12 mesi fa | 0

Risposto
Automatic Transfer Switch Model
Simscape and Simscape Electrical provide the option to model a transfer switch. The easiest way is to use a circuit breaker (sin...

circa un anno fa | 0

Risposto
What can I learn from Mathway's "Three-Phase Systems and Machines"?
This page aims to show how to simulate a three-phase power system containing electrical machines and other three-phase models. ...

circa un anno fa | 0

Risposto
DC Microgrid modeling and control
Simscape Electrical is provinding many examples in the microdgrid area that can be used as a starting point. Check for example: ...

circa un anno fa | 0

Risposto
Error with running a Simulink model.
Without the files is not easy to tell where the problem is. I suspect when you run the first model some parameters from the work...

circa un anno fa | 0

Risposto
Direct matrix converter with svm control
A good starting point is Simscape Electrical. You can check this example: https://www.mathworks.com/help/sps/ug/three-phase-mat...

circa un anno fa | 0

Risposto
How we modeling PWM inverter with PI and PR current controllers with grid connection
There is not such thing as the best controller. It all depends on specific requirements. For a starting point with grid connecte...

circa un anno fa | 0

Risposto
vector control of of WRSM ( wound rotor synchronous motor
From the diagram is difficult to spot the issue as everything is in a subsystem. I assume there is a sign mismatch somewhere. Fo...

circa un anno fa | 0

Risposto
Design and Simulation of DC to AC Power Inverter with Star Connected Load
It is not exaty clear what you are trying to achieve and what have you tried already. A Motor drive can act as a DC-AC system an...

circa un anno fa | 0

Risposto
Switch block in simulink does not connect
I suspect the blocks you are trying to connect are from two different technologies. Without a model is imposible to point to any...

circa un anno fa | 0