Azzera filtri
Azzera filtri

Serial Port won't clear after halting debugging

3 visualizzazioni (ultimi 30 giorni)
Fritz Sonnichsen
Fritz Sonnichsen il 16 Ago 2011
Commentato: Ivan Peric il 23 Gen 2018
I am debugging code using the serial port. If I exit the debug session normally via <shift>F5, I cannot reopen the serial port upon restarting a new debug session. I get the error listed at the bottome of this post. I have to shutdown matlab completely to clear everything.
I can understand why the port is still open (it was not closed upon exiting debug), however I need a way to "clear" it and reopen it after the next debug session.
I issue the 'delete(instrfindall)' at the start of the program but this does not work.
Thanks for any ideas, Fritz
==============================================
??? Error using ==> serial.fopen at 72
Cannot connect to the COM5 port. Possible reasons are another
application is connected to the port or the port does not exist.
Error in ==> spectrometer_monitor at 39
fopen(s);
  2 Commenti
Ariel
Ariel il 27 Ago 2013
Hello Fritz.
My name is Ariel and I'm dealing the same problem. have you found solution?
Thank you
Ariel
Ivan Peric
Ivan Peric il 23 Gen 2018
You can try this: -right click myCoumputer -properties -device manager -serial -ports -right click your port -disable -enable

Accedi per commentare.

Risposte (1)

Adam
Adam il 16 Ago 2011
instrreset
is your friend!
Clear the serial object then issue an instrreset.
  4 Commenti
Adam
Adam il 16 Ago 2011
From MATLAB documentation on delete:
"Remarks
When you delete obj, it becomes an invalid object. Because you cannot connect an invalid serial port object to the device, you should remove it from the workspace with the clear command."

Accedi per commentare.

Categorie

Scopri di più su Use COM Objects in MATLAB in Help Center e File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!