Packet Input (Simulink) returning 0s
1 visualizzazione (ultimi 30 giorni)
Mostra commenti meno recenti
EDIT: This works in Normal mode, but not External mode!
In External Mode, the Packet Input block in Simulink only returns 0s when connected to my serial port device. The baudrate is set correctly, the device is verified as streaming ASCII by connecting to a terminal and watching the stream.
Block error and Data Ready both stay at 0, and I see the data being streamed from the device when the program is running. This is an FTDI serial port interface.
Thoughts? I'm running Real-Time Windows Target in External Mode.
0 Commenti
Risposte (1)
Jan Houska
il 22 Ago 2014
The situation you describe (Data Ready is 0) happens when the incoming data is not accepted by the device, for whatever reason. The fact that the data output stays at the initial value of 0 is only a consequence of that. Please try to enable the Data Error port and check there. If the output of this port goes to 1, something with the incoming data is wrong after all (baud rate, parity, data format, whatever).
2 Commenti
Jan Houska
il 25 Ago 2014
I have just tested RS232 in both Normal and External modes, both work for me. I have used the rtpacketio example with driver changed to Serial Port and a loopback connector on the port. Do you think you could try something similar to reduce the possibility of some unrelated issue?
Vedere anche
Categorie
Scopri di più su Target Computer Setup in Help Center e File Exchange
Prodotti
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!