Hi,
i have this issue with slow simulation time for a stable first order tranfers function.

I've tested it with and without the Dead zone and I get the same results. The Scope1 show a intense oscillation of the output.
Thanks
Alexandre
1 Commento
Aniruddha Katre
il 3 Set 2014
This behavior stems from the fact that the time-step taken by the solver is so large that it fails to capture the dynamics of the system, which has a bandwidth of 200000 rad/s.
Consistent with the Nyquist sampling theorem, if you run the simulation using a fixed-step solver with step size of around 1/400000, then you will not observe this kind of oscillation.