I am using a repeating sequence to generate a triangle wave for PWM in Simulink.
In specifying the time values for the repeating sequence, when I use values such as: [0 0.00005 0.0001] (corresponding to a 10kHz waveform), the waveform looks fine.
When I use a smaller time value of: [0 0.000005 0.00001] (corresponding to a 100kHz waveform), the waveform looks all distorted.
How can I "set" the timestep in the simulation, so that the triangle wave is not distorted?

Risposta accettata

Azzi Abdelmalek
Azzi Abdelmalek il 21 Set 2014
In model configuration parameter, choose your solver type to fixed step, and just below set your your fundamental sample time. http://www.mathworks.com/help/simulink/ug/choosing-a-solver.html#f11-41982