Build errors with Simulink CAN Transmit block on Raspberry Pi with CAN_MESSAGE as input
4 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Hello,
I have a problem with the CAN-Transmit block from the Raspberry Pi Simulink hardware support package. If I put a CAN Pack block in front of the Transmit block and set the input datatype to CAN_MSG for the Transmit block, I get the following error message during the build process:
The data type of input port 1 is 'CAN_MESSAGE'. MATLAB System block 'CAN Transmit' only supports built-in, binary point scaling [Slope=1.0, Bias=0.0], Simulink enumeration, and bus data types.
Tested with Simulink 2021b and 2022a.
Does anyone have the same problem or a solution for me?
1 Commento
Henry Rake
il 5 Set 2022
Hey Alexander,
i have the same issue. Were you able to fix it?
Kind regards
Henry
Risposte (1)
Vikky Patil
il 10 Nov 2022
Try enabling "Output as bus" in CAN Pack block and then rebuild the model