I designed two bus signals with the same data type.
One signal is the initializing signal.
The other is a signal that is checked every cycle.
A merge block was used to merge two signals, but the following error occurred.
***************************************************************************************************************************************************************
Cannot propagate non-bus signal from 'Output Port 1' of 'AppSelfTest/P_u32_s_APP_CST_RetryLimitsReachedStatus_DE_merge' to 'Input Port 1' of 'AppSelfTest/P_u32_s_APP_CST_RetryLimitsReachedStatus_DE' because the destination block requires a bus signal.
***************************************************************************************************************************************************************
Is there any way to solve this issue?
  3 Commenti
WJKIM
WJKIM il 7 Lug 2022
Hi
I kept trying to solve this problem.
I found this cause and solved it.
The cause is that the signal name of two tags in bus creator block was different.
Thanks for your interest!
Saurabh
Saurabh il 7 Lug 2022
Hi, glad to hear that you solved the problem.