Problem with Simscape Onramp

70 visualizzazioni (ultimi 30 giorni)
Joydeep
Joydeep il 26 Set 2022
Risposto: NABIL il 18 Mar 2024
Hello!
I'm trying to access the Simscape Onramp course in browser mode and the Simulink window refuses to open even after waiting for a long time.
The one time it did open, it showed an error when clicking on Submit for the very first assignment.
"Unrecognized function or variable 'simmechanics.sli.internal.register_datatypes'. (Figure atached)
Thanks!
  3 Commenti
Sanaullah-ghous
Sanaullah-ghous il 23 Dic 2023
Unrecognized function or variable 'simmechanics.sli.internal.register_datatypes'.
jay
jay il 13 Feb 2024
=== Analysis (Elapsed: 0.66 sec) ===
Error:Unrecognized function or variable 'simmechanics.sli.internal.register_datatypes'.

Accedi per commentare.

Risposte (6)

Kannan
Kannan il 29 Set 2022
Hi Joydeep,
  1. Coming to the problem of accessing the Simscape Onramp, Please ensure that your version of MATLAB is R2021a or later before proceeding. This can be confirmed by typing in >> ver at the MATLAB command line.
  2. You can choose to download the latest version if you have a licence or request for a free trial here : https://www.mathworks.com/campaigns/products/trials.html .
  3. When on a trial licence please acccess onramp courses from your MATLAB desktop application. Here are the steps to access Simscape Onramp from the MATLAB Command Window:
  • Open MATLAB, and ensure that you are logged into your account. Check the upper right corner to verify that you are signed in.
  • Type the command below in the Command Window:
learning.simulink.launchOnramp('simscape')
Now coming to the error message Undefined function or variable 'simmechanics.sli.internal.register_datatypes'. The root cause of this issue is under investigation. The workaround is to execute the following command from MATLAB Online.
>> addpath(fullfile(matlabroot,'toolbox/physmod/sm/sli/m'))
  6 Commenti
CAMILO ANDRES
CAMILO ANDRES il 26 Set 2023
Thanks!!!
Richard
Richard il 28 Set 2023
Came here looking for the same issue with the browser version of Simscape Onramp.
Happy to confirm the workaround command worked, and I'm able to continue on!

Accedi per commentare.


Shubham
Shubham il 6 Feb 2024
>> addpath(fullfile(matlabroot,'toolbox/physmod/sm/sli/m'))

Ashwini
Ashwini il 6 Feb 2024
Error:Unrecognized function or variable 'simmechanics.sli.internal.register_datatypes'.

Ashwini
Ashwini il 6 Feb 2024
Error:Unrecognized function or variable 'simmechanics.sli.internal.register_datatypes'.

khalfallah
khalfallah il 18 Mar 2024
Error:['SimscapeOnramp/Controlled Voltage Source', 'SimscapeOnramp/Electrical Reference', 'SimscapeOnramp/Gear Box', 'SimscapeOnramp/Ideal Rotational Motion Sensor', 'SimscapeOnramp/Inductor', 'SimscapeOnramp/Inertia', 'SimscapeOnramp/Mechanical Rotational Reference', 'SimscapeOnramp/Mechanical Rotational Reference1', 'SimscapeOnramp/PS-Simulink Converter', 'SimscapeOnramp/Resistor', 'SimscapeOnramp/Rotational Electromechanical Converter', 'SimscapeOnramp/Rotational Hard Stop', 'SimscapeOnramp/Simulink-PS Converter']: Each physical network must be connected to exactly one Solver Configuration block. There is no Solver Configuration block connected to Physical Network with the following blocks: 'SimscapeOnramp/Controlled Voltage Source'
'SimscapeOnramp/Electrical Reference'
'SimscapeOnramp/Gear Box'
'SimscapeOnramp/Ideal Rotational Motion Sensor'
'SimscapeOnramp/Inductor'
'SimscapeOnramp/Inertia'
'SimscapeOnramp/Mechanical Rotational Reference'
'SimscapeOnramp/Mechanical Rotational Reference1'
'SimscapeOnramp/PS-Simulink Converter'
'SimscapeOnramp/Resistor'
'SimscapeOnramp/Rotational Electromechanical Converter'
'SimscapeOnramp/Rotational Hard Stop'
'SimscapeOnramp/Simulink-PS Converter'

NABIL
NABIL il 18 Mar 2024
thank you Sm

Categorie

Scopri di più su Foundation and Custom Domains in Help Center e File Exchange

Prodotti


Release

R2020b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by