How to use SOC Estimator (Coulomb Counting )

43 visualizzazioni (ultimi 30 giorni)
MAHENDRAN A
MAHENDRAN A il 19 Ott 2022
Commentato: Gokul Gopakumar il 16 Gen 2024
What ports should i add for SOC Estimator (Coulomb Counting ) block. Can i get any sample models using that block

Risposte (1)

Steve Miller
Steve Miller il 23 Ott 2022
The SOC Estimator (Coulomb Counting) block requires the initial state of charge (SOC) and current being drawn from the battery as inputs. It outputs an estimate of the SOC.
You can add this very easily to the shipping example BatterySOCEstimation.slx - see screenshot below.
Thanks
--Steve
  7 Commenti
Haad Yousaf
Haad Yousaf il 25 Lug 2023
Hello Steve,
Can the Coulomb counting SOC estimator block be configured such that the output SOC from the block behaves as if 1 simulation second is 1 hour. My current profile is modeled such that 1 simulation second is 1 hour real world data, so the SOC has to behave according to that in 1 simulation second.
Is this possible, and if so how can it be done?
I would greatly appreciate your help
Gokul Gopakumar
Gokul Gopakumar il 16 Gen 2024
Hello Steve,
I had a similar question regarding the Coulomb Counting method using the SOC Estimator Block. I have a table in Matlab workspace with Current in Amperes and Time in hours. The test ran for almost 76 hours with data acquisition every 100ms. In between there is a Rest phase for 2 hrs where the current is 0 A. So overall i have a table with 1851958 rows of data. I am giving this as input in the current block. The Initial SOC is taken from a SOC OCV Lookup Table depending on the voltage. When i run the programme, the block is only executing for 10Sec. (becuase of discrete Integrator?) How should i adapt the block as to run the programme for the entire length of the Table ?

Accedi per commentare.

Prodotti


Release

R2022b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by