Warning: The value of enumeration member 'VT_OK' differs from when the enumeration was saved. 'VT_OK' will be loaded with the new value.
10 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
When I run the Test Sequence created in Simulink Test Manager, I get the following warnings in the command window:
Warning: The value of enumeration member 'VT_OK' differs from when the enumeration was
saved. 'VT_OK' will be loaded with the new value.
Warning: The value of enumeration member 'IGN_SNA' differs from when the enumeration was
saved. 'IGN_SNA' will be loaded with the new value.
Warning: The value of enumeration member 'VSL_INACTIVE' differs from when the
enumeration was saved. 'VSL_INACTIVE' will be loaded with the new value.
Please let me know how to remove this warning.
0 Commenti
Risposta accettata
Nishan Nekoo
il 9 Nov 2022
These warnings can be resolved as follows:
1) Find the Simulink.Parameter objects or other data objects in the data dictionary that use the enumeration mentioned in the warning message
2) Make minor modifications to the data object (e.g., change the description) and then save the changes
2 Commenti
Più risposte (0)