Adjust Label after resampling medical volume
Mostra commenti meno recenti
I resampled a medical volume (nifti) following these instructions:
ctFile=medicalVolume('E:\git\maskRCNN\norm\LD\case_00167.nii.gz');
targetVoxelSize=[3.11 1.59 1.59];
ratios = targetVoxelSize ./ ctFile.VoxelSpacing;
origSize = size(ctFile.Voxels);
newSize = round(origSize ./ ratios);
origRef = ctFile.VolumeGeometry;
origMapping = intrinsicToWorldMapping(origRef);
tform = origMapping.A;
newMapping4by4 = tform.* [ratios([2 1 3]) 1];
newMapping = affinetform3d(newMapping4by4);
newRef = medicalref3d(newSize,newMapping);
newRef = orient(newRef,origRef.PatientCoordinateSystem);
newCTFile = resample(ctFile,newRef,Method='linear');
write(newCTFile,"E:\git\maskRCNN\norm\LD\case_00167");
ctFile is an image with Voxels 512x512,103 , taken from the kits19 challenge (https://github.com/neheller/kits19/tree/master/data)
However, the label (also a nifti file) that marked a organ on the original image (ctFile), does not mark the same area on the new, resampled image (newCTFile). I assume I need to tranform the label too. How do I do that?
1 Commento
cr
il 14 Nov 2022
Please consider providing more information like data sizes, code etc for community to be able to understand and possibly answer.
Risposta accettata
Più risposte (0)
Categorie
Scopri di più su Image Processing Toolbox in Centro assistenza e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!