Azzera filtri
Azzera filtri

how can i get the value of specific enthalpy at the reference temperature in block of gas properties?

5 visualizzazioni (ultimi 30 giorni)
how can i get the value of specific enthalpy at the reference temperature in block of gas properties?
now, i don't have any idea about specific enthalpy at the reference temperature.
plz help me.

Risposta accettata

Yifeng Tang
Yifeng Tang il 22 Dic 2022
Hi Jiseung,
I believe that parameter is just to specify a reference point (like 0 degC on temperature scale) for the specific enthalpy. The actual change in the enthalpy (energy transfer) is based on the difference between two states, so the value at the reference doesn't really matter. The default value in this block is 420 kJ/kg, which is the value from REFPROP for dry air in the "pseudo-pure fluids" category. REFPROP itself contains another dry air in the "predefined mixture", in which at the same temperature the specific enthalpy is 293.4 kJ/kg. So, it's just a starting value; it doesn't really matter; it's the difference, i.e. Cp and R values, that matters.
Hope this helps.