Can I run a parameter sweep for Load-Flow Analysis programmatically when using a powergui block?
1 visualizzazione (ultimi 30 giorni)
Mostra commenti meno recenti
MathWorks Support Team
il 20 Gen 2023
Modificato: MathWorks Support Team
il 16 Apr 2023
Can I run a parameter sweep for Load-Flow Analysis programmatically when using a powergui block?
Risposta accettata
MathWorks Support Team
il 20 Feb 2023
Modificato: MathWorks Support Team
il 16 Apr 2023
Load-Flow Analysis can be performed programmatically using the “power_loadflow” function. Please refer to the following link for further information:
For the case in which you would like to run a parameter sweep with subsequent Load-Flow Analysis programmatically, you can either add this line to the for loop that simulates the model or in the callbacks of the model. Please refer to the following links for more information on model callbacks:
Depending on whether you would like to run the Load-Flow Analysis before or after each simulation, you can choose to add the command for Load-Flow Analysis in the “StartFcn” or “StopFcn” model callback.