Can we equate or un-equate the two MV's of the MPC controller in command line?
3 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Sarala Gurijala
il 15 Feb 2023
Commentato: Sarala Gurijala
il 17 Feb 2023
Hi
I have the system with 2inputs, 1output, in that I need to give the constraints for 2MV's and the constraint range(min&max) of those 2MV's is same. but I need to give the condition that, MV1 should not be equal to the MV2. can I give this condition in MPC command line coding? please suggest me.
Thank you in advance..
0 Commenti
Risposta accettata
Emmanouil Tzorakoleftherakis
il 16 Feb 2023
Hello,
A couple of points first:
1) I am assuming your MVs are continuous (if they are discrete, what you are asking is not supported because you would need a mixed-integer NLP solver and Model Predictive Control Toolbox does not have one out of the box yet).
2) A constraint of the form MV1 ~= MV2 does not make much sense for floating point calculations. So basically you can just design your linear MPC without this constraint and it is very unlikely that MV1 == MV2 considering again numerics etc. So I am assuming that you want the 2 MVs to be significantly different, for example |MV1-MV2|>= 0.1.
This kind of constraint you cannot implement with linear MPC, so you have to use nonlinear MPC (see how to create custom constraints here) With that in mind, you can do something like sqrt((MV1-MV2)^2) >=0.1 or equivalent.
Hope that helps
Più risposte (0)
Vedere anche
Categorie
Scopri di più su Refinement in Help Center e File Exchange
Prodotti
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!