Azzera filtri
Azzera filtri

Time-domain convolution doesn't match Frequency-domain multiplication in MATLAB

1 visualizzazione (ultimi 30 giorni)
I wonder why these two lines of codes generate very different results:
subplot(1,2,1);
semilogx(abs(X.*HPF));
subplot(1,2,2);
semilogx(abs(fft(conv(ifft(X),ifft(HPF),'same'))));
I mean, regardless of the actual values of X and HPF, spectrum derived from multiplying X and HPF should have the same results as the spectrum derived from convoluting their time-domain impulse responses (which is derived by ifft). But my results show that they are quite different. In my case x is the input signal that have a few sine wave components at different frequencies and HPF is a high-pass filter, but the two expressions should always yield the same results right? I'm confused.

Risposta accettata

Matt J
Matt J il 22 Feb 2023
Modificato: Matt J il 22 Feb 2023
Note that conv() implements linear convolution, not circular convolution.
  5 Commenti
Tianjia
Tianjia il 22 Feb 2023
I just found out another, easier way. Use cconv(x, hpf, N) and the result is correct! Thank you for reminding me of the circular and linear thing! I've been thinking about this for almost a week.

Accedi per commentare.