How to enable trigger out signal of Basler USB 3.0 camera ?
9 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Jenifer NG
il 2 Mar 2023
Commentato: Carl Haugan
il 2 Mag 2023
Dear All,
I connect my Basler camera to matlab through GenTL toolbox.
Could anyone success to enable trigger out signal of Basler camera ? Please guide me
It has a function to generate trigger out signal base on 'Exposure Active'.
This is mycode export from Image Acquisition toolbox.
v = videoinput("gentl", 1, "Mono8");
info = imaqhwinfo(v);
width_res = info.MaxWidth;
height_res = info.MaxHeight;
v.ROIPosition = [width_res/2 height_res/2 1280 1280];
src = getselectedsource(v);
src.AutoTargetBrightness = 0.5019608;
src.ExposureTime = 1000;
src.LineSelector = "Line3";
src.LineMode = "Output";
img = getsnapshot(v);
Thanks and Regards!
Han
0 Commenti
Risposta accettata
Vanshika Vaishnav
il 9 Mar 2023
Configure camera for FrameStart trigger mode and specify external triggering signal input line and desired trigger condition.
This requires setting the TriggerSelector first; once a TriggerSelector value is selected, setting a trigger property (for example, TriggerMode to 'on') applies only to the specified trigger mode (FrameStart).
for more information, refer this MATLAB answer:-
1 Commento
Carl Haugan
il 2 Mag 2023
Hello, I read the original question as trying to use the camera's output line to indicate 'Exposure Active'.
I'm using a Ximea camera and would also like to use this functionality.
The question is marked as answered, but the link is to using the trigger input line, it doesn't seem to provide any insights into configuring camera output line.
Are there any examples showing the configuration of camera ouputs?
Thanks for any help,
Carl