Using Ld and Lq inductance values for IPMSM
    21 visualizzazioni (ultimi 30 giorni)
  
       Mostra commenti meno recenti
    
    Milos Bozovic
 il 28 Apr 2023
  
    
    
    
    
    Risposto: Raghunath Rachabattuni
    
 il 30 Giu 2023
            Hello!
I want to implement FOC for IPMSM. I am using the 'Permanent Magnet Synchronous Machine' model in Simulink. 
It asks for armature inductance value, but I only have Ld and Lq values. Can I just put [Ld Lq] in that field?
0 Commenti
Risposta accettata
  Raghunath Rachabattuni
    
 il 30 Giu 2023
        Additionally, you may also use the Ld Lq and fluxPM values using the blocks MTPA Control Reference and LUT based PMSM Control Reference blocks too. 
Additionally you can refer to the following pages for how to use both the blocks
0 Commenti
Più risposte (1)
  Supraja
    
 il 8 Mag 2023
        Assuming that you want to implement FOC using ipmsm. You can use Ld and Lq  I understand that you want to implement IPMSM using FOC.  
Here is the documentation link for the same: https://www.mathworks.com/help/sps/ug/power-motordrive-IPMSM-FOC.html?searchHighlight=ipmsm%20foc&s_tid=srchtitle_ipmsm%20foc_1 
0 Commenti
Vedere anche
Categorie
				Scopri di più su Specialized Power Systems in Help Center e File Exchange
			
	Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!