I can't connect a load component to the signal source

2 visualizzazioni (ultimi 30 giorni)
i want to connect between "constant power load" component to "signal generator" component, the line just not conect and the end of line that exit from "constant power load" component is a circle and the end of line that exit from"signal generator" component is aמ arrow, as you see here:
what is the problem?
how can i fix it?
thenks.

Risposta accettata

Nikhil Baishkiyar
Nikhil Baishkiyar il 15 Giu 2023
The signal generator block belongs to Simulink while the Constant Power Load belongs to Simscape. They belong to different modelling environments (you can see that the color of blocks are different) and cannot be connected together directly.
You must use a Simulink-PS converter to interface Simscape with Simulink and PS-Simulink converter to interface Simulink with Simscape.
  2 Commenti
Nikhil Baishkiyar
Nikhil Baishkiyar il 15 Giu 2023
Modificato: Nikhil Baishkiyar il 15 Giu 2023
I assume you want to make something like this
amit
amit il 15 Giu 2023
Thank you for the answer.
In order to simplify the model, is there a power load component from another family that suitable to signal generaor without PS-converter? Or alternatively, is there signal source from another family that suitable to power load componnt?

Accedi per commentare.

Più risposte (0)

Categorie

Scopri di più su Composite Components in Help Center e File Exchange