Azzera filtri
Azzera filtri

No block called 'AirFrame' could be found

7 visualizzazioni (ultimi 30 giorni)
Bentolila Yedidia
Bentolila Yedidia il 26 Giu 2023
Commentato: Diya Tulshan il 26 Giu 2023
'Airframe' is a Subsystem in my Simulink model. Using set_param to change a parameter (Gain) value inside 'Airframe' it suceeds. But when trying to do the same for a Subsystem inside 'Airframe' it fails. Why??

Risposte (1)

Diya Tulshan
Diya Tulshan il 26 Giu 2023
Hii Bentolila Yedida,
I understand you are unable to change the gain parameter for a subsystem inside 'Airframe'.
The 'set_param' function allows you to modify parameters of Simulink blocks, including subsystems.To change a parameter value inside a subsystem that is nested within another subsystem, you need to specify the full path to the parameter you wish to modify.
Here's an example that describes the condition:-
set_param('Model/Airframe/SubsystemName','Gain','Value ');
For better understanding of the 'set_param', kindly refer to following link:-https://in.mathworks.com/help/simulink/slref/set_param.html
  3 Commenti
Bentolila Yedidia
Bentolila Yedidia il 26 Giu 2023
OK I found the problem: The Name of the Subsystem. Sometimes when entering the name we leave a blank space (at beginning or at the end) which cannot be easily noticed. Only by Checking in 'Properties' we can see the mistake.
Diya Tulshan
Diya Tulshan il 26 Giu 2023
Hope this did solve your problem!