- Open the “powergui” block and make sure the “Simulation type” is discrete.
- Navigate to “Preferences” tab.
- Expand solver details for nonlinear elements.
- Enter a large value in the Maximum number of iterations.
When I do load flow analysis it is not converging?
67 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Preethi Sebastian
il 17 Lug 2023
Commentato: Cory Paquet-Clouston
il 26 Lug 2024
When I do load flow analysis of a 31 bus power system model ,error as "unable to converge in 50 iterations is shown".Is it possible to increase the number of iterations .I have done in simulink
0 Commenti
Risposta accettata
Prathamesh
il 26 Lug 2023
Hi,
I understand that you are encountering the error message “unable to converge in 50 iterations”. This issue is occurring because the number of iterations required to converge is more than the max iterations limit defined in “powergui” block.
Please follow the steps mentioned below to resolve this problem:
Please refer to the documentation attached below for more information.
I hope this resolves your issue.
2 Commenti
Cory Paquet-Clouston
il 26 Lug 2024
As a side note, as it might happened to other people:
I was getting the "unable to converge in 50 iterations" error until I noticed that the frequency was set to 0 instead of 60 (or 50, depending on your use case)
Più risposte (2)
Sonam Dorji
il 14 Mar 2024
This step does not work for me. I am using Kundur two area system with induction motor as load in area 2. Any other possible solution for it.
Thank you.
0 Commenti
Dail
il 23 Giu 2024
There is a switch between a three-phase power supply or three programmable AC power supplies and the distribution network. loadflow does not consider the switch, and the calculated power generation and consumption are inconsistent
0 Commenti