Slip in Asynchronous Block - Induction Machine Squirrel Cage
2 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
How do I add Slip to the Asynchronous Block - Induction Machine Squirrel Cage, when the Induction Motor slip is 60RPM for a 11kW 4Pole motor 50Hz 1440 rpm.
When no value for slip is given, then the simulation shows a max speed of 1500 RPM
0 Commenti
Risposta accettata
Joel Van Sickel
il 28 Lug 2023
the block can only give you input for the initial condition of slip, but this does not determine your slip once the model is running. The physics of the system you have created determines the slip, and you can only explicitly control slip by adding a closed loop controller to the system. If you are trying to match the steady state performance of your machine, you will need to set its other parameters and the appropriate load to recreate a steady state value of 1440 RMP with a 50Hz input signal. Inthis case, are you applying at 11kW load?
Più risposte (0)
Vedere anche
Categorie
Scopri di più su Motor Drives in Help Center e File Exchange
Prodotti
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!