unable to resolve cooling plate error

4 visualizzazioni (ultimi 30 giorni)
hi there,
i am modelling a battery module with cooling plate. while running the simulation, i am getting this error;
"Error compiling Simscape network for model molicell_module_with_cooling_plate.
Caused by:
Connection 'connect(NewModule.BottomExtClnt,Parallel_Channels.Side1)' is found to be connecting arrays of nodes of inconsistent sizes: '1x14' and '1x196'. The arguments in a connection must be of the same size."
kindly help in resolving this error. Thanks
  3 Commenti
SUDEEP SINGH RAWAT
SUDEEP SINGH RAWAT il 26 Lug 2023
Thanks for responding sir. I have used battery builder app to build the battery module with 14X14 cylindrical cells. ambient coolant path and coolant thermal path are set to " cell based internal resistance". i have attached the model along with cooling plate parameters.i am not sure if the parameters of cooling plate matching with nodes of battery module? please help.
Hyunwoo
Hyunwoo il 27 Lug 2023
I have the same problem, did you solve it?

Accedi per commentare.

Risposta accettata

Joel Van Sickel
Joel Van Sickel il 28 Lug 2023
I think you need to set your number of nodes to 14 and not 14x14 for the cooling plate. If that doesn't solve it, please share your model instead of screen shots to get further assistance.

Più risposte (0)

Prodotti


Release

R2023a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by