xcp on serial Custom board c2000

66 visualizzazioni (ultimi 30 giorni)
ali
ali il 20 Ago 2023
Risposto: ali il 26 Ago 2023
I connected my custom c2000 320f28335 mcu board via sci_a with com port to simulink for xcp debugging, but there is time out error on connection.
Is there any specific hardware configuration?
matlab version 2022b.
the error is :
Could not connect to target application: XCP internal error: timeout expired, in response to XCP CONNECT command
  1 Commento
ali
ali il 23 Ago 2023
Sci-a connected to pc via USB to TTL device, on com port and I configured this port number in hardware configuration in simiulink and also I checked pin number of sci-a

Accedi per commentare.

Risposta accettata

ali
ali il 26 Ago 2023
in my case the problem was due to Gnd connection of board and USB to TTL device, I had not connected Gnd,
after I connect it, external mode works correctly