IF-ELSE block in simulink

Assalamualaikum & hi all
I just want to know is it possible to end the IF-ELSE block execution process at certain point. Because in my model the IF_ELSE block keeps execute,unless i stop the model. My model run in real-time process using Wincon software

 Risposta accettata

Kaustubha Govind
Kaustubha Govind il 3 Nov 2011

0 voti

You can put the If-Else subsystem inside an Enabled Subsystem that you can disable/enable at any point in the simulation.

5 Commenti

Mohd Hazny Aziz
Mohd Hazny Aziz il 4 Nov 2011
thanks for reply...for example if it being disable it mean that the if-else subsystem will execute until it enable back right??
I suppose you meant to say "the if-else subsystem will *NOT* execute until it is enabled"? Yes, that's correct.
Mohd Hazny Aziz
Mohd Hazny Aziz il 9 Nov 2011
yup...but in my understanding if the if-else block run in real-time..the model keep on updated depending on the sample time..do the enabled subsystem able to disable/enable during that time??
Yes, the enabled subsystem will also look at the control signal at every time-step. If the control signal disables it, it will not run the contents of the subsystem.
Mohd Hazny Aziz
Mohd Hazny Aziz il 11 Nov 2011
k..thanks Kaustubha Govind...i got it

Accedi per commentare.

Più risposte (0)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by