getting negative open voltage in pv array
5 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
hello,
I model pv array block with input excel using signal editor and repeating sequences. I just put goto block in 'm' port of pv array to see voltage diagram. after i run my voltage which is open circuit voltage is in negative part of V-t
if anyone what is my problem please help me.
3 Commenti
Risposte (1)
Aishwarya
il 27 Dic 2023
Hi Fatemeh,
I understand that you are getting negative open circuit voltage from the “PV array” block, which is not the expected result.
In your Simulink model, the “PV array” block is used in a discrete system with large sample times. By default, the "Break algebraic loop in internal model" parameter is selected in the “PV array” block. For discrete system, the algebraic loop in “PV array” block is required to get an iterative, accurate solution for the highly non-linear diode characteristic. I would suggest deselecting this option which is present in “Advanced” tab.
For more information, please refer to below MATLAB Answers post:
- https://www.mathworks.com/matlabcentral/answers/2051407-pv-array-output-fluctuation-with-static-inputs
- https://www.mathworks.com/matlabcentral/answers/466337-why-do-i-get-algebraic-loop-error-when-using-pv-array-block
Kindly refer to the “Advanced” section of the below documentation for more details on “PV array” block: https://www.mathworks.com/help/sps/powersys/ref/pvarray.html
I hope this helps!
Best Regards,
Aishwarya