Hi Nishant,
This error occurs when some operation in the model returns "Inf" or "NaN" output. To debug this error, open Configuration Parameters and navigate to Diagnostics > Data Validity. Set the diagnostic "Inf or NaN block output" to error. When you run your simulation, you will get the error as follows:
An error occurred while running the simulation and the simulation was terminated
Caused by:
Block 'BlockName' outputs 'NaN' for element x of output port x at major time step 0
Where 'BlockName' is the block in which the error is thrown.
This block either divides by 0 or outputs NaN, which creates an Inf which generates this error. Therefore, avoid division by zero in the logic and check operations for possible NaN outputs.
  3 Commenti
R
R il 12 Apr 2024
It's difficult to identify the specific issue based solely on the image. Could you please attach the Simulink model along with your response so that I can examine it more closely?

Accedi per commentare.

Più risposte (1)

Mirza
Mirza il 10 Mar 2025
I'm having the same problem as you while designing my MPPT, my solution was to add a small capacitor pararel to the + and - of the PV Panel, 0.00001 should be good. Try it and see if it works