How to delay an output signal by milliseconds
4 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
My modelling requirement includes a need to delay an input signal (of type 'BOOL') by up to 10 milliseconds. I have tried using Transport Delay block but it returns an error saying this only works for 'Double' data types and not 'BOOL'. I also tried standard delay block but this only accepts integer delay length values. Does anyone have a walkaround step in mind I could try?
0 Commenti
Risposta accettata
R
il 4 Apr 2024
Hi,
As a workaround, you can convert the input signal from 'bool' to 'double' using the Data Type Conversion Block and then pass it in the Transport Delay block. Here is the documentation for reference:
0 Commenti
Più risposte (0)
Vedere anche
Categorie
Scopri di più su Simulink PLC Coder in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!