Azzera filtri
Azzera filtri

Stop Simulink Model Update via Callback

2 visualizzazioni (ultimi 30 giorni)
I have a callback on a custom block that checks a bus selector for missing signals, at the start of the model update routine. Based on the results of that update, I send an sldiagviewer.reportError(errMsg) command to Matlab. What I want it to do is stop the update cycle at that point because I know it will throw an error downstream in ~5 minutes where the user will have to fix the problem. Instead, Simulink just continues runnign the update cycle until Simulink decides it cannot continue anymore.
So my question is basically how to stop the update cycle?

Risposta accettata

Fangjun Jiang
Fangjun Jiang il 15 Apr 2024
Instead of sldiagviewer.reportError(errMsg), if you do error(errMsg), it should stop.
  3 Commenti
Fangjun Jiang
Fangjun Jiang il 15 Apr 2024
Modificato: Fangjun Jiang il 15 Apr 2024
okay, try modelName([],[],[],'term'). I think model update is equivalant as modelName([],[],[],'compile')
RIchard
RIchard il 16 Apr 2024
Modificato: RIchard il 16 Apr 2024
Your orignal comment is correct and I have accepted it. Somehow, I was incorrectly calling `error`, and it was going to the matlab version instead of simulink.

Accedi per commentare.

Più risposte (0)

Prodotti


Release

R2020a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by