Need help on an error regarding a Simulink model
4 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
I have a ongoing study on a model regarding insulation coordination which I downloaded from this link https://www.mathworks.com/matlabcentral/fileexchange/108549-insulation-coordination-in-a-generating-station/?s_tid=LandingPageTabfx, it shows an error when I tried to run the model. Not sure what I'm doing wrong, hoping for a solution.
I have attached the original file(project1F30X2_m) and a slightly modified version(model2).
Error Encountered: Specialized Power Systems cannot solve this circuit. Please check for one the following two possibilities : 1) The circuit solution is undetermined. This problem arises when transformers with no magnetization branch (Rm=inf; Lm=inf) are connected together. --> Specify a magnetizing branch with finite Rm and/or Lm parameter values. 2) Circuit solution is inuccurate due to a badly scaled circuit. This is usually caused by a too wide range of resistance values (ex 1e-6 ohm and 1e6 ohm in the same circuit). --> Try to reduce range of resistance values. For example, reduce snubber resistances.
0 Commenti
Risposte (1)
Neha
il 16 Mag 2024
Hi,
I encountered a similar problem and was able to resolve it by specifying a discrete solver within the "powergui" block. The solver type can be selected in the "Solver" tab of the "powergui" block.
Hope it helps!
Vedere anche
Categorie
Scopri di più su Electrical Systems in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!