Park and clarke transformation inconsistencies

7 visualizzazioni (ultimi 30 giorni)
Marc Arriola
Marc Arriola il 20 Mag 2024
Risposto: Joel Van Sickel il 3 Set 2024
I am running a simulink model of a PMSM where I transform the three phase currents to the dq frame, afterwards I transform it back to the abc frame and lastly I transform it again to dq frame. In the last transformation I found that the d current is inconsistent with the one of the first step while the q current remains the same. I have checked all the transformation blocks and seem correct. Has any of you experienced this before?
Thanks in advance.

Risposte (1)

Joel Van Sickel
Joel Van Sickel il 3 Set 2024
the model wasn't shared so I'll have to speculate here: If the d/q transforms are providng strange results, it is likely that they are not set to the same axis. There are many d/q transfromer blocks in different libraries so it is easy to mix them up such that they aren't using the exact same reference frame.

Categorie

Scopri di più su Electrical Block Libraries in Help Center e File Exchange

Prodotti


Release

R2023b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!