about test point during code generation
9 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
wenchao zhang
il 10 Lug 2024
Commentato: wenchao zhang
il 10 Lug 2024
hello, what's the purpose of test point in code generation, an how it realized. i'm not clear about this.
0 Commenti
Risposta accettata
Fangjun Jiang
il 10 Lug 2024
If it is a test point, code generation makes sure to allocate dedicated memory and generate variable for it so you can observe this signal. If it is not a test point, there might be a varialbe (e.g. TempVar) for this but this TempVar might be re-used later in the code so you won't be able to observe the value of this variable reliably. In aother case, if there are two consective Gain blocks (times 5 and then times 10), the code might be optimized as times 50. If the signal in between these two Gain blocks is a test point, then you will be able to observe the signal after times 5.
3 Commenti
Fangjun Jiang
il 10 Lug 2024
Modificato: Fangjun Jiang
il 10 Lug 2024
If it is a time varying signal, Yes. If it is a "parameter", meaning the value never changes during a run, then INCA has better way to observer that single value.
"test point" forces to generate code for the point. You might want to use signal logging for measurement.
Check the user guide for INCA too.
Più risposte (1)
Himanshu
il 10 Lug 2024
Modificato: Himanshu
il 10 Lug 2024
Hi,
I see that you want to understand the purpose of test points in code generation.
A test point is a signal in Simulink that is guaranteed to be observable when using a Floating Scope block in a model. Simulink allows you to designate any signal in a model as a test point.
Designating a signal as a test point exempts the signal from model optimizations, such as signal storage reuse and block reduction. These optimizations can render signals inaccessible and unobservable during simulation. Signals designated as test points will not have algebraic loops minimized, even if the "Minimize algebraic loop occurrences" option is selected.
Test points are primarily intended for use when generating code from a model with Simulink Coder. Marking a signal as a test point ensures that it remains observable and is not affected by model optimizations that can obscure its behavior.
Please refer to the documentation below to learn more about configuring signals as test points and the appearance of test points in the generated code.
Configure Signals as Test Points: https://www.mathworks.com/help/simulink/ug/working-with-test-points.html
How Generated Code Stores Internal Signal, State, and Parameter Data - Appearance of Test Points in the Generated Code: https://www.mathworks.com/help/rtw/ug/how-generated-code-stores-internal-signal-state-and-parameter-data.html#f1043283
I hope this helps.
0 Commenti
Vedere anche
Categorie
Scopri di più su Inputs in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!