Simulink data type conversion, single to uint16.

22 visualizzazioni (ultimi 30 giorni)
Hello,
I'm using simulink and I need to convert from a single to a uint16.
Could a kind soul kindly explain why the output of a single (with range 0-2pi) equates to an uint16 of zero?
Here is an example:
And here is the output of that example:
There are a number of uint16 signals in my model with range 0-4000 (I am reading from sevreral ADC). All behave as expected. Just this conversion, in this instance.
  5 Commenti
Jamie
Jamie il 19 Set 2024
Modificato: Jamie il 20 Set 2024
Thanks Daniel, Walter. The signal is being output to a host model using a data serial output. The data serial output transmits two signals of type uint16. An example from the mcb;
Yes, I'm using data type conversion block. Sending multiple signals (more than 2), using PU units / a different data type would be preferable.
Jamie
Jamie il 25 Set 2024
I still continue to see scaling during data type conversions. This seems very unusual.
Ex. Scaling from 0-1 to 0-4045

Accedi per commentare.

Risposta accettata

Hitesh
Hitesh il 19 Set 2024
Modificato: Hitesh il 19 Set 2024
Hi Jamie,
I am assuming that you have used "Data Type Conversion" block, and the conversion to "uint16" resulted in unexpected values due to the default integer rounding mode being set to "floor" in Block Parameters. If you change the rounding mode to "round," you will achieve the expected results when converting from "single" to "uint16".
  1 Commento
Jamie
Jamie il 21 Set 2024
Modificato: Jamie il 21 Set 2024
Thanks all for the comments! Got around it by altering the model and removing the uint conversin blocks.

Accedi per commentare.

Più risposte (0)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!