Simulink R2020b DataStore Memory and String support. Cannot use a string as an Inital Value
2 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
In Simulink R2020b, I cannot use the DataStore Memory block with a string Initial Value although the DataType is set on "string".
The error message is the following : "Invalid setting in '<SYSTEM>/Data Store Memory' for parameter 'InitialValue'.
This should be support as per the documentation : https://fr.mathworks.com/help/releases/R2020b/simulink/ug/simulink-strings.html
Am I doing anything wrong ?
0 Commenti
Risposte (1)
Jaimin
il 9 Ott 2024
Modificato: Jaimin
il 9 Ott 2024
To resolve the error, one workaround is to use the “Initialize Function” block to assign a string value to the “Data Store Memory” block. This works because the “Initialize Function” block is a preconfigured Subsystem block that executes during a model initialization event.
Kindly refer to the following images to understand how to use the "Initialize Function" block.
For more information on “Initialize Function” block kindly refer following MathWorks Documentation.
I hope this will be helpful.