FMU issue while setting parameter

5 visualizzazioni (ultimi 30 giorni)
Saurabh Dhakate
Saurabh Dhakate il 28 Ott 2024
Risposto: Gayatri il 28 Ott 2024
We have an FMU that imports successfully into Simulink. However, I'm struggling to set parameters from the workspace. I've tried using various Simulink callbacks but it doesn't seem to affect the FMU's parameters. I want to set parameters once at the start of the simulation.

Risposta accettata

Gayatri
Gayatri il 28 Ott 2024
Hi Saurabh,
You can modify the parameters using the following MATLAB commands:
blockPath = 'model_name/block_name';
blockHandle = getSimulinkBlockHandle(blockPath, true);
set_param(blockHandle, 'parameter_name', 'parameter_value');
Please refer the below documentations for 'set_param' and 'getSimulinkBlockHandle' functions:
I hope it helps!

Più risposte (0)