Simulink.Parameter Value

87 visualizzazioni (ultimi 30 giorni)
Ayodeji
Ayodeji il 13 Nov 2024 alle 19:03
Commentato: Ayodeji il 18 Nov 2024 alle 18:33
What should the parameter Value be in the model explorer when the Data type is a user defined bus structure?
  1 Commento
Ayodeji
Ayodeji il 18 Nov 2024 alle 18:33
I was able to copy the user defined bus structure from the external structure and rename the bus structure. Thanks.

Accedi per commentare.

Risposte (1)

Sreeram
Sreeram il 15 Nov 2024 alle 6:27
Hi Ayodeji,
I assume that you mean how to add the value for the Simulink.Parameter object of Bus type so that it is reflected in the Model Explorer.
Here is an example on how to create a Simulink.Parameter object:
1. Create a struct object and assign fields as required:
Sinusoidal_MATLABStruct = struct;
Sinusoidal_MATLABStruct.Chirp = 0;
Sinusoidal_MATLABStruct.Sine = 0;
2. Create a Simulink.Parameter object and assign Value and other attributes as needed:
Sinusoidal_Param = Simulink.Parameter;
Sinusoidal_Param.Value = Sinusoidal_MATLABStruct;
Sinusoidal_Param.DataType = 'Bus: Sinusoidal';
Sinusoidal_Param.Complexity = 'real';
Sinusoidal_Param.CoderInfo.StorageClass = 'Auto';
This will add a parameter object ‘Sinusoidal_Param’ in the Base Workspace. You may drag and drop it to the Model Workspace if required.
You may read more about how to configure parameter values here:
I hope this helps.

Categorie

Scopri di più su Simulink Coder in Help Center e File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by