Can i use battery pulse discharge data to calibrate the table-based battery model?

2 visualizzazioni (ultimi 30 giorni)
Hello,
I am in between developing a lithium ion battery pack for thermal analysis. For this, i have taken table-based battery model. I also have DC electronic load tester which can perform pulse discharge test of the lithium ion cell. As far as i know, the HPPC test data is required to calibrate the battery cell model which is based on pulse charge and discharge of the lithium ion cell, but i only have discharging option. Can i calibrate my battery pack model with the experimental data of pulse discharge? Also, if any other option is available, please let me know.
Thank you.

Risposta accettata

Mike Sasena
Mike Sasena il 25 Nov 2024
Hi Sudeep. Check out this example on fitting equivalent circuit battery models to test data. The process works with whatever data you give it, but if you provide only discharge data, you will only characterize the discharge behavior. You would expect different resistance in charge and discharge operation.
  2 Commenti
SUDEEP SINGH RAWAT
SUDEEP SINGH RAWAT il 18 Dic 2024
Thank you for the comment. My purpose is calibrating cell model with experimental discharge data and i am focused in discharging cell at different discharge current. Is there any other way to calibrate the cell model other than "Model-based Calibration" since i am using macbook and the toolbox is not supported for MacOS. Please reply. Thank you.
Mike Sasena
Mike Sasena il 18 Dic 2024
Hi Sudeep. If you don't have any way to access a Windows or Linux machine, you could try using tools like Simulink Design Optimization or the Optimization Toolbox to set up the parameter estimation.