Uchenna Johnpaul
il 28 Nov 2024 alle 15:51
Modificato: Uchenna Johnpaul
il 11 Dic 2024 alle 11:49
I make reference to the above question but in particular, I will like to get a more detailed explanation from Sabin who has answered the question in two different occasions. Could you kindly give more insight on the exact use of Programmable Voltage Source (Three-Phase) or a Controlled
Voltage Source (Three-Phase). The attachment is what I have done with Programmable Voltage Source (Three-Phase). How do I use it to get external input connected as it could done with Dynamic Load (Three-Phase) which is used for balanced load?
0 Commenti
Risposte (1)
Shivam Gothi
il 29 Nov 2024 alle 4:43
As per my understanding, you are tring to implement a three phase unbalanced dynamic load. You want the external inputs “P” (Active power) and “Q” (reactive power) for controlling it.
As correctly pointed out by you, the “Dynamic Load (Three-Phase)” is used for balance three-phase dynamic load. In order to implement unbalanced dynamic load, you can go via any of methods as suggested by @Sabin in the MATLAB answer post:
Those methods are very good to simulate unbalanced three phase supply. But as per my understanding, if you want to simulate three-phase unbalance dynamic loads with “P” and “Q” as inputs, the below given workarounds will be good to start with.
1) Use “Dynamic Load” block
This block is found inside the library “Simscape / Electrical / Passive”. Refer to its documentation:
It is used to simulate unbalanced dynamic load for single phase supply. However , you can use it with three phase by making the following changes:
1) Open the “block parameters” and change the “Load Type” property to “AC” as shown in below figure:
2) You can connect them in star or delta configuration for three phase as shown below:
As it is an unbalanced dynamic three-phase load, you have to provide the active power and reactive power inputs for all the three phases as seen in the above attached images.
I hope you find it useful !
4 Commenti
Shivam Gothi
il 10 Dic 2024 alle 16:32
Can you please share the simulink model or its screen-shot?
It will be usefull in investigating how you have connected VI sensor and power supply to the load. It will also help to find the reason behind high measurement.