Problem after Converting the simulink model from R2024a to R2022b

4 visualizzazioni (ultimi 30 giorni)
I have a Simulink model (1D model using simscape blocks) in R2024a. I have to generate .exe file. Bz of situation, I wanted to degrade my model to R2022b. But when I run that model in R2022b, it causing multiple errors. I have rearranged the simscape blocks there according to R2022b. Even then this error persists. What are the precautions should be taken to eliminate this error?
  2 Commenti
Yukthi S
Yukthi S il 9 Dic 2024
Can you share the error message and the simulink model for better understanding?

Accedi per commentare.

Risposta accettata

Vangala
Vangala il 11 Feb 2025
Hi guys,
Thanks for anwering the question above. I had solved it myself.
In R2022b, When you use pressure and temperature sensor, connect its A to main stream flow and B to the absolute reference. Remove unwanted sensors in the whole loop.
This method solved the issue: "No of variables greater than no. of equations".

Più risposte (1)

Saurabh
Saurabh il 11 Dic 2024
Modificato: Saurabh il 20 Dic 2024
This seems to be a possible bug try running the model using 'sim(bdroot)' and then clicking the hyperlinks which appear in the command window.
I hope this helps