Simscape voltage sensor block shows slightly lower value
Mostra commenti meno recenti
Hi,
I am experiencing a strange behaviour when using a simple model with voltage source and voltage sensor using Simscape library blocks.
I have set up the input voltage reference to 690 Vrms line-to-line, but after voltage sensor I am measuring slightly smaller voltage. The logical conclusion would be there is a series impedance somewhere in either Controlled Voltage Source (Three-Phase) or Current and Voltage Sensor (Three-Phase) block, but I do not know where.
Could anyone please clarify what is happening. I do not understand what I am seeing?! And can I make them show the same value?


Model is attached.
Regards, MB
2 Commenti
(Formatting issue on mobile)
\newline...
I don’t know where to start. However, a stable linear time-invariant (LTI) transfer function cannot perfectly track a pure sine-wave reference signal without additional inputs.
\newline...
Assuming you can derive the equivalent or approximate transfer function of the system G(s) using Simulink Linearization Tool, when you pass a pure sine wave r(t) = A·sin(ω·t) into a stable LTI system G(s), the steady-state output will always take the form:
\newline...
y(t) = A|G(jω)|·sin(ω·t + ∠G(jω))
\newline...
where |G(jω)| is the magnitude and ∠G(jω) is the phase of the system.
\newline...
For perfect tracking y(t) = r(t), two strict conditions must be met simultaneously at the specific frequency ω:
\newline...
1. Magnitude condition: |G(jω)| = 1
2. Phase condition: ∠G(jω) = 0°
\newline...
Perhaps other users can show you the mathematical solution for achieving perfect tracking, followed by the Simulink/Simscape config.
Torsten
circa 6 ore fa
The values at t=0 already differ. Make sure they agree.
To this end, AI gives me this answer:
Transient Stabilization & Initialization
Simscape networks need to find an initial mathematical equilibrium at the very beginning of the simulation run (t=0).
- The Issue: Unless configured otherwise, alternating current (AC) networks start at zero and experience a brief startup transient. Since RMS calculations rely on a sliding time window (typically one full cycle), the calculation will naturally look "diluted" or smaller during the first cycle because it includes t=0 data.
- The Solution: Open your model's Solver Configuration block and check the option Start simulation from steady state. This forces Simscape to pre-calculate the AC steady state before time steps begin. Also, ensure your circuit has an Electrical Reference block properly connected to ground.
Risposte (0)