Simscape model yeilds Simulink "State Derivative Fail" Error
12 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Uing the Simscape Pneumatic Piston Chamber Block in a simulation runs fine with area, extension and dead volume paramters set to .2m^2, 1m and 1e-5 respectivly. When I change to my actual device parameters of 28cm^2, 2.54cm and .7cm Simulink reports a State Derivative Fail error.
Why?
0 Commenti
Risposte (1)
Sabin
il 23 Dic 2025
This error indicates numerical instability in the simulation. When using a smaller area and stroke and a much larger dead volume relative to size, the system dynamics will change drastically likely increasing the stiffness. This can cause the solver to fail if the time step is too large or the model is too stiff for the default solver settings. Double-check your units and parameter values for consistency. If that's all correct try reducing the solver step size or switching to a ode23t or daessc solver (introduced in R2021a).
0 Commenti
Vedere anche
Categorie
Scopri di più su Foundation and Custom Domains in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!