Sum of a signal in simulink
49 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Sam136
il 4 Ago 2015
Modificato: Yeow Yu Leong
il 9 Giu 2024
In my Simulink model, current value of a signal should be added to all previous value of the same signal. I've used integrator with initial value of zero to find it; however the result is different from what I find in Matlab through "sum" or "trapz" function. The solver is continuous with fixed step size. Any thought to resolve this issue. or any other block to use for this purpose instead of integrator?
0 Commenti
Risposta accettata
Azzi Abdelmalek
il 4 Ago 2015
Modificato: Azzi Abdelmalek
il 4 Ago 2015
function y=fcn(u)
persistent a
if isempty(a)
a=0
end
y=u+a;
a=y;
You can also use a discrete transfer function 1/(z-1)
1 Commento
Più risposte (1)
Sean de Wolski
il 4 Ago 2015
You could also use a unit delay:
1 Commento
Azzi Abdelmalek
il 4 Ago 2015
He is asking for all previous values. This will calculate out(n)+out(n-1)