[Coretcl 2-106] Specified part could not be found
16 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Hi - I am running HDL Coder in Matlab and trying to get the Embedded Systems Integration to work. I have a Xilinx Zynq-7000 ZC706 eval board. I am getting the following error: [Coretcl 2-106] Specified part could not be found.
I attach an image for more clarity. Some guidance as to how to resolve this issue would be appreciated.
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/153258/image.png)
Thank, -D
0 Commenti
Risposte (1)
Wang Chen
il 14 Gen 2016
Hi Diego, it looks like the Vivado tool you have do not have xc7z045 device support. Are you using Xilinx Vivado Webpack edition? The Zynq chip on ZC706 board need the system edition.
0 Commenti