matlab coding to s-function level 2 coding.

2 visualizzazioni (ultimi 30 giorni)
Hi,
Using Matlab, i can initialize the particle filter like this:
for i = 1 : N
xhatplus(:,i) = xhat + sqrt(P) * [randn; randn; randn];
end
Now, i want to use simulink s-function level 2. how should i coding it?
function DoPostPropSetup(block)
block.Dwork(3).Name = 'xhatplus';
block.Dwork(3).Dimensions = N*3;
block.Dwork(3).DatatypeID = 0;
block.Dwork(3).Complexity = 'Real';
block.Dwork(3).UsedAsDiscState = true;
function InitializeConditions(block)
block.Dwork(3).Data = ??
Any advise? Thanks.
  2 Commenti
Kaustubha Govind
Kaustubha Govind il 31 Gen 2012
It depends on what xhat and P stand for in your filter.
dab483
dab483 il 31 Gen 2012
my coding is something like below:
function DoPostPropSetup(block)
%% Setup Dwork
block.NumDworks = 3;
block.Dwork(1).Name = 'xhat'; %% states
block.Dwork(1).Dimensions = 3;
block.Dwork(1).DatatypeID = 0;
block.Dwork(1).Complexity = 'Real';
block.Dwork(1).UsedAsDiscState = true;
block.Dwork(2).Name = 'P'; %% covariance matrix
block.Dwork(2).Dimensions = 9;
block.Dwork(2).DatatypeID = 0;
block.Dwork(2).Complexity = 'Real';
block.Dwork(2).UsedAsDiscState = true;
N=1000;
block.Dwork(3).Name = 'xhatplus';
block.Dwork(3).Dimensions = N*3;
block.Dwork(3).DatatypeID = 0;
block.Dwork(3).Complexity = 'Real';
block.Dwork(3).UsedAsDiscState = true;
function InitializeConditions(block)
block.Dwork(1).Data = [3e5; -2e4; 1e-3];%%xhat
block.Dwork(2).Data = [1e6;0; 0; 0 ;4e6; 0;0;0;10]; %%P
block.Dwork(3).Data = ??
function Outputs(block)
block.OutputPort(1).Data = block.Dwork(1).Data;%% xhat
%%endfunction
function Update(block)
P=reshape(block.Dwork(2).Data,3,3);
xhatplus=reshape(block.Dwork(3).Data,3,N);

Accedi per commentare.

Risposta accettata

Kaustubha Govind
Kaustubha Govind il 3 Feb 2012
Oops, just realized that you are asking about the InitializeConditions function, and not Update or Outputs. The initial condition of your state depends on the dynamics of your system or application - it's hard for us to tell what it should be. The only thing that I can say is that it needs to be of size 3000. For example, for zero-initial condition, you can say:
block.Dwork(3).Data = zeros(3, N);