How to connect a Simscape Fluids/Centrifugal Pump to Specialized Technology/Asynchronous Machine

3 visualizzazioni (ultimi 30 giorni)
Hello,
I would like to connect a Specialized Technology/Asynchronous Machine to Fluids/Hydraulics/Centrifugal Pump.
How do I do this?
Thanks in advance.

Risposta accettata

McSpark
McSpark il 6 Ott 2016
Hello,
You can do this by changing the Asynchronous Machine to have its Mechanical Input set to Mechanical rotational port
To do this double click the block, go to the Configuration Tab and select Mechanical rotational port drop down under Mechanical input:
Yuo can now directly connect the motor to the pump
  1 Commento
Sofia Lobera
Sofia Lobera il 30 Lug 2021
Once you have connected the pump with the simscape block, how can just tell the pump there ir a constant difference of pressure correspomding to ro*g*head? As if it was a constant source of pressure difference. Which block should i connect?

Accedi per commentare.

Più risposte (0)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by