Why does the 'LoadFcn' Callback of a commented block get executed in Simulink R2024b?

25 visualizzazioni (ultimi 30 giorni)

Risposta accettata

MathWorks Support Team
MathWorks Support Team il 6 Nov 2024 alle 0:00
Modificato: MathWorks Support Team il 12 Nov 2024 alle 19:13
As for Simulink R2024b, this is the expected behavior.
We can classify the block callbacks in two categories: edit time and run time.
Edit time callbacks like the 'LoadFcn' callback need to execute even if the block is commented out. Just to display the commented block in the model, the block needs to be loaded, and the load callback is triggered. A similar behavior is observed with the 'DeleteFcn' and 'DestroyFcn' callbacks.
On the other hand, callbacks that are runtime (not needed for editing) like 'InitFcn' and 'StartFcn' are not triggered for commented out blocks and inactive variants.

Più risposte (0)