Tuning transfer function to get only positive parameters using Simulink
3 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
I have a transfer function with order three in both numerator and denominator. I am tuning the block using the control system tuner to find the best coefficients for the block for a desired function. My question is how to tell the tuner that the coefficients to be found must be positive values?
ex: tf=(a1*s+1)(a2*s+1)(a3*s+1)/((b1*s+1)(b2*s+1)(b3*s+1))
I want to find the values of the parameters all a & b to be positive values. Any idea? Thanks
0 Commenti
Risposte (1)
Sebastian Castro
il 17 Apr 2017
For all tuned blocks, you can expand the variable name and set their "Minimum" and "Maximum" values. If you set a minimum of 0, does it work?

Sebastian
3 Commenti
Vedere anche
Categorie
Scopri di più su Classical Control Design in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!